Water dripping back through bathroom ceiling extractor fan
Warm shower steam cooling inside uninsulated loft ducting, condensing on duct walls, and running backwards through the ceiling fan grille.
Severity
medium
SafetyWater dripping into electrical fan housings creates risk of short circuits, motor burnout, and fire hazards.
Symptoms
- · Rusty or dirty water droplets dripping from extractor fan grille onto floor after showering
- · Water stain ring discoloring ceiling plasterboard directly surrounding the extractor casing
- · Extractor fan motor rattles, buzzes, or trips the circuit breaker due to water ingress
- · Flexible ducting in attic sags under the weight of accumulated pooled water
What you should do
- 01Wrap all ducting runs passing through cold unheated loft spaces with pre-insulated foil-faced duct wrap (minimum 25mm thickness).
- 02Install an inline vertical condensation trap with drainage tube leading to an external waste pipe or gutter.
- 03Ensure horizontal duct runs maintain a slight downward slope (5-10mm per meter) towards the external discharge vent.
- 04Replace sagging flexible accordion ducting with rigid smooth-walled PVC ducting to reduce airflow resistance and pooling.
Switch off mains electricity at the consumer unit before inspecting or disassembling bathroom extractor casings.